• 6SL3210-5BE27-5CV0 FREQ REG 400V 3F 7.5KW | 6SL32105BE275CV0FREQREG400V3F7.5KW• Width: 240.000, Height: 206.500, Depth: 172.500, With control unit: -, Number of digital inputs: 4.000, Number of digital outputs: -, Number of analogue inputs: 2.000, Number of analogue outputs: 1.000, Supporting protocol for LON: false, Number of HW-interfaces industrial Ethernet: 0.000, Number of HW-interfaces RS-232: 1.000, Number of HW-interfaces RS-422: 0.000, Number of HW-interfaces RS-485: 1.000, Number of HW-interfaces serial TTY: 0.000, Number of HW-interfaces USB: 0.000, Number of HW-interfaces parallel: 0.000, Number of HW-interfaces other: 1.000, With optical interface: false, Supporting protocol for TCP/IP: false, Supporting protocol for ASI: false, Supporting protocol for PROFIBUS: false, Supporting protocol for CAN: false, Supporting protocol for INTERBUS: false, Supporting protocol for KNX: false, Supporting protocol for MODBUS: true, Supporting protocol for Data-Highway: false, Supporting protocol for DeviceNet: false, Supporting protocol for SUCONET: false, Supporting protocol for other bus systems: true, Degree of protection (IP): IP20, With PC connection: false, Supporting protocol for SERCOS: false, Supporting protocol for INTERBUS-Safety: false, Mains voltage: 380.000, Mains frequency: -, 4-quadrant operation possible: false, Number of interfaces PROFINET: 0.000, Type of converter: U converter, Number of phases output: 3, Number of phases input: 3, Integrated breaking resistance: true, Application in industrial area permitted: true, Application in domestic- and commercial area permitted: false, Max. output frequency: 550.000, Max. output at linear load at rated output voltage: 7.500, Max. output at quadratic load at rated output voltage: 7.500, Relative symmetric net voltage tolerance: -15.000, Relative symmetric net frequency tolerance: 5.000, Supporting protocol for AS-Interface Safety at Work: false, Supporting protocol for DeviceNet Safety: false, Supporting protocol for EtherNet/IP: false, Supporting protocol for Foundation Fieldbus: false, Supporting protocol for PROFINET CBA: false, Supporting protocol for PROFINET IO: false, Supporting protocol for PROFIsafe: false, Supporting protocol for SafetyBUS p: false, Max. output voltage: 480.000, Nominal output current I2N: 16.500, Supporting protocol for BACnet: -, Degree of protection (NEMA): -
• 6SL3210-5BE27-5CV0 FREQ REG 400V 3F 7.5KW | 6SL32105BE275CV0FREQREG400V3F7.5KW• Width: 240.000, Height: 206.500, Depth: 172.500, With control unit: -, Number of digital inputs: 4.000, Number of digital outputs: -, Number of analogue inputs: 2.000, Number of analogue outputs: 1.000, Supporting protocol for LON: false, Number of HW-interfaces industrial Ethernet: 0.000, Number of HW-interfaces RS-232: 1.000, Number of HW-interfaces RS-422: 0.000, Number of HW-interfaces RS-485: 1.000, Number of HW-interfaces serial TTY: 0.000, Number of HW-interfaces USB: 0.000, Number of HW-interfaces parallel: 0.000, Number of HW-interfaces other: 1.000, With optical interface: false, Supporting protocol for TCP/IP: false, Supporting protocol for ASI: false, Supporting protocol for PROFIBUS: false, Supporting protocol for CAN: false, Supporting protocol for INTERBUS: false, Supporting protocol for KNX: false, Supporting protocol for MODBUS: true, Supporting protocol for Data-Highway: false, Supporting protocol for DeviceNet: false, Supporting protocol for SUCONET: false, Supporting protocol for other bus systems: true, Degree of protection (IP): IP20, With PC connection: false, Supporting protocol for SERCOS: false, Supporting protocol for INTERBUS-Safety: false, Mains voltage: 380.000, Mains frequency: -, 4-quadrant operation possible: false, Number of interfaces PROFINET: 0.000, Type of converter: U converter, Number of phases output: 3, Number of phases input: 3, Integrated breaking resistance: true, Application in industrial area permitted: true, Application in domestic- and commercial area permitted: false, Max. output frequency: 550.000, Max. output at linear load at rated output voltage: 7.500, Max. output at quadratic load at rated output voltage: 7.500, Relative symmetric net voltage tolerance: -15.000, Relative symmetric net frequency tolerance: 5.000, Supporting protocol for AS-Interface Safety at Work: false, Supporting protocol for DeviceNet Safety: false, Supporting protocol for EtherNet/IP: false, Supporting protocol for Foundation Fieldbus: false, Supporting protocol for PROFINET CBA: false, Supporting protocol for PROFINET IO: false, Supporting protocol for PROFIsafe: false, Supporting protocol for SafetyBUS p: false, Max. output voltage: 480.000, Nominal output current I2N: 16.500, Supporting protocol for BACnet: -, Degree of protection (NEMA): -